사양
| Nominal Inlet Service Pressure | 700 bar / 10,153 psi |
| Maximum Inlet Rated Pressure | 875 bar / 12,691 psi |
| Minimum Inlet Pressure | At least 150% of outlet pressure<br>*Operating at pressures below this minimum pressure could limit the maximum flow rate |
| Design Proof Pressure | 150% of nominal inlet service pressure |
| Pressure Rating | Per Criteria of ANSI/ASME B31.3 |
| Outlet Pressure Range | 10-30 bar / 145-435 psi |
| Leakage | Bubble-tight |
| Operating Temperature | -40°F to +185°F / -40°C to +85°C |
| Flow Capacity | Cv=0.17; 5 g H<sub>2</sub>/sec |
| Decaying Inlet Characteristic | 6.2 mbar per 6.9 bar change in inlet pressure / 0.09 psi per 100 psi change in inlet pressure |
| Filter | 10 µm<br>*The 10 µm filter is for initial system assembly protection. The product is designed to be used with particulate free hydrogen. Your system should be designed with proper filtration before the regulator to protect against contamination. |
| Body | Aluminum 6061-T6 with Clear Anodic Coating |
| Seat | Polyimide |
| O-Rings | Nitrile |
| Main Valve | 316 SST |
| Valve Spring | 316 SST |
| Piston | 316 SST |
| Sensor | Aluminum 6061-T6 |
| First and Second Stage Spring | 17-7 SST |
| Remaining Parts | 300 Series SST, Aluminum 60661-T6, Polyimide |
| Cleaning | CGA 4.1 and ASTM G93 |
| Weight | 3.5 lbs / 1.6 kg |